Inquiry

Contact Form

Biomass/Bagasse /Coco Nut Fired Double Drums Steam Boiler

Biomass/Bagasse /Coco Nut Fired Double Drums Steam Boiler, Find Details and Price about Biomass Fired Rick Husk Fired from Biomass/Bagasse /Coco Nut Fired Double Drums Steam Boiler – QINGDAO HAMMER INDUSTRIES CO., LTD.

Function:Water Boiler, Steam Boilers
Fuel:Coal-Fired
Installation:Packaged Boiler
Structure:Water Tube
Media:Steam
Water Circulation:Forced Circulation
Drum Placement:Horizontal Boiler
Pressure:Low Pressure
Manufacturing Level:A
Burning Style:Chamber Combustion Boiler
Usage:Industrial
Trademark:QD Hammer
Transport Package:Naked by 40′ Ot or Flat Rack Containers
Origin:Qingdao
HS Code:84021900

Basic Info:

US$40,000.00-200,000.00 / Piece FOB Price:
1 Piece Min. Order:
Qingdao, China Port:
10sets/Month Production Capacity:
L/C, T/T, D/P, Western Union, Paypal, Money Gram Payment Terms:
84021900 HS Code:

Category & Tag:

Biomass/Bagasse /Coco Nut Fired Double Drums Steam Boiler

SZL Series Steam Boiler Specification
SZL water tube easy installation(assembled) boiler has 2 vertical steam drums, and the
innovative horizontal cyclone-fired combustion chamber, which could effectively enhance
the thermal efficiency and reduce the flue gas emission concentration. The flue gas emission
concentration is lower than 100 mm/nm3, the flue gas blackness is lower than Ringelmann
level 1,which enables the boiler to be used in the first-class environment protected area.
The boiler installs one cast iron economizer at its back body, the fire-gate applies the
chamber-segregated ventilation structure, which is easy to adjust. The separate-layer coal
supply device could be chosen according to the customer requirement. Advantages of
such boiler are: strong power, high thermal efficiency, 110% override capability,
compactly designed, small floor area.

Boiler ModelSZL6-1.25/1.6/2.5-AIISZL8-1.25/1.6/2.5-AIISZL10-1.25/1.6/2.5-AIISZL12-1.25/1.6/2.5-AIISZL15-1.25/1.6/2.5-AIISZL20-1.25/1.6/2.5-AIISZL25-1.25/1.6/2.5-AII
Rated Evaporation Capacityt/h681012152025
Operation PressureMpa1.25/1.6/2.51.25/1.6/2.51.25/1.6/2.51.25/1.6/2.51.25/1.6/2.51.25/1.6/2.51.25/1.6/2.5
Steam TemperatureºC194//204/226194//204/226194//204/226194//204/226194//204/226194//204/226194//204/226
Water-inlet TemperatureºC20202020105105105
 Heating Efficiency%≥78≥78≥80≥80≥81≥81≥81
Area of Boiler Heating Surfacem3147.8175220388443578626
Area of Stokerm37.69.611.7214.217.222.626.3
Coal AvailableII type bitumite,low heat capability:17700-21000KJ/kg
Water PumpModel2GC-5×62½GC-6×6DG12-25×7DG15-35×5DG15-35×5DG25-35×5DG46×30
Motor PowerKW15/18.515/18.518.5/2222/3022/3030/3737/45
Blast FanModelG6-41-13
NO7.1A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-73-11
NO11D
G4-68-10D
Ventilationm3/h5349-103549369-181379369-181379369-181379369-181373610033173-
58856
 Wind PressurePa1697-22702535-33912535-33912535-33912535-339127302313-3401
 Motor  PowerKW7.518.518.518.518.53745
Induced Draft FanModelY6-41-13
NO10C
Y6-41-13
NO11.2D
Y6-41-13
NO11.2D
Y6-41-13
NO11.2D
Y8-39-13
NO10D
GY20-15Y4-68
NO12.5D
Ventilationm3/h32144-
16604
41773-
21578
41773-
21578
41773-
21578
45007330860611-
110772
 Wind PressurePa2575-34442764-36972764-36972764-3697320535153765-2589
Motor PowerKW3745455590110132
Dimensions of Biggest Parts for ShipmentM7.83×3.34×
3.46
8.82×3.34×
3.46
8.0×3.5×
2.7
7.2×3.3×
3.6
8.0×3.3×
3.6
10.6×3.35×3.6910.8×4.46×3.76
Weight of Biggest Parts for ShipmentT48/51/5356/58/6096/97/98102/103/104107/108/109152/154/156210/212/214

Remark: This parameter is just for reference, for exact parameter, subject to our drawings.

Boiler FAQs

Q: What different types of boilers are available?

DZL type steam/hot water boiler
SZL type steam /hot water boiler
SHL type steam /hot water boiler
WNS type steam /hot water boiler
SZS type steam /hot water boiler
SZW type steam /hot water boiler
CFB type steam boiler
YLW type thermal oil boiler/heater
YYL(W) type thermal oil boiler/heater
WNS type thermal oil boiler/heater
SZS type thermal oil boiler/heater
SZW type thermal oil boiler/heater
Waste heat recovery boiler
Steam generator

Q: What is a fire tube steam boiler?

A fire tube steam boiler is a boiler where the combustion gases from the burner are channeled through tubes that are surrounded by the fluid to be heated. The boiler body is the pressure vessel and contains the fluid. In most cases, this fluid is water that will circulate for heating purposes or become steam for use in processing.
Each set of tubes through which the combustion gas passes, before making a turn, is considered a “step”. Consequently, a three-step boiler will have three sets of pipes with the outlet located at the rear of the boiler.

Q: What’s advantages of our boiler?

Wide Range of Fuel Type
Applicable for a various of light oil, furnace oil, natural gas, LNG, biogas, coke gas, methanol, biodiesel, etc.

High Thermal Efficiency
New and unique design with high thermal efficiency, which save running cost of buyer

Unique Control System
Unique three-elements control system with PID unit covered PLC, inverters, and HMI to reach high level automatic running of boiler

Q: What is the turndown ratio of our boilers?

our boilers feature turndown ratios of 5:1, means the boiler’s minimum operating load is 20% of the boiler’s full capacity (100% capacity)

Q: How do I choose the right boiler?

Firstly, check the actual steam pressure and consumption required at present, and discuss with management there are extra steam required or not in next five years.
Secondly, confirm the boiler fuel type, then we will provide you an optimal boiler that take all factors in consideration.

Q: How long does an industrial steam boiler last?

The normal service life of a steam boiler is 10 to 20 years, provided that proper care and maintenance routines are applied to the feedwater and interior of the boiler.
When considering steam boiler replacement, the three most important aspects to consider are safety, economy and changing requirements to perform the function for which it is operating.

Q: What services for industrial boilers does our offer?

we offers its customers the following services for industrial steam boiler, thermal oil boiler and waste heat recovery boilers and steam generators:

Customized boiler designs.
Super quality boiler product
Installation and commissioning service
Operators training service
Lifetime maintenance service.

Q: What safety features do steam boiler have?

Boiler shutdown protection due to water level low
Boiler shutdown protection due to continuous water level low
Boiler shutdown protection due to steam pressure high
Safety valve over pressure protection.
Automatic FWP on / off

Q: What is the lead time of our boiler

The subject boiler will be delivered within 60 -90 days based on boiler capacity

Q: What primary components for boilers are there?

The most common accessories are:
Burner
Economizer and condenser
Feed water pump
Thermal deaerator (if necessary)
Chimney
Control panel
Instrument gauges and valves
we supplies all types of complementary equipment for industrial steam boilers, and designs new equipment and tools if they are necessary for the final installation to meet its clients’ expectations.

Q: What are the optional items of boiler for buyer choose from

Steam and feed water flow meter
Periodic blowdown expander (if necessary)
Continuous blowdown expander (if necessary)
Thermal deaerator (if necessary)

Q: What is the supply scope of boiler arranged by buyer

Whole civil works engineering by our design drawing
All connecting piping (steam, feed water piping)
All connecting cables (motor cables, single cables, main power supply cable)
Some connecting valves from feed water pump point
Chimney manufacture on site by our design drawing
Balance flue gas ducting manufacture on site by our design drawing
Thermal deaerator

Q: How does boiler warranty work?

The subject boiler is covered by a twelve months warranty against mechanical and/ or factory defects from date of test-run or 18 months from the date of shipment whichever comes earlier.
we shall repair or replace the components, parts or accessories covered by warranty that had become inoperative within the warranty period but not covered caused by faulty operation from the buyer.
we will provide lifetime service for boiler with cost when its warranty expired.

Q: Who will be fitting my new boiler?

Simply, a local professional boiler installing company will install the subject boiler under our engineer’s instruction and supervision

Q: How long will my installation & commissioning take?

Typically, the whole installation & commissioning work may take 1-4 months based on the subject boiler capacity.

Q: How often should I maintain my boiler?

Overhaul inspection and maintenance: 1-3 month
we will provide detail brochure regarding how and when to do maintenance work during boiler running.

Company Info

Related Products