Coal/Biomass/Multi Fuel Fired Steam Boiler

Coal/Biomass/Multi Fuel Fired Steam Boiler, Find Details and Price about Biomass Fired Rick Husk Fired from Coal/Biomass/Multi Fuel Fired Steam Boiler – QINGDAO HAMMER INDUSTRIES CO., LTD.

Description

SZL Series Steam Boiler Specification

SZL water tube easy installation(assembled) boiler has 2 vertical steam drums, and the
innovative horizontal cyclone-fired combustion chamber, which could effectively enhance
the thermal efficiency and reduce the flue gas emission concentration. The flue gas emission
concentration is lower than 100 mm/nm3, the flue gas blackness is lower than Ringelmann
level 1,which enables the boiler to be used in the first-class environment protected area.
The boiler installs one cast iron economizer at its back body, the fire-gate applies the
chamber-segregated ventilation structure, which is easy to adjust. The separate-layer coal
supply device could be chosen according to the customer requirement. Advantages of
such boiler are: strong power, high thermal efficiency, 110% override capability,
compactly designed, small floor area.

Boiler Model SZL6-1.25/1.6/2.5-AII SZL8-1.25/1.6/2.5-AII SZL10-1.25/1.6/2.5-AII SZL12-1.25/1.6/2.5-AII SZL15-1.25/1.6/2.5-AII SZL20-1.25/1.6/2.5-AII SZL25-1.25/1.6/2.5-AII
Rated Evaporation Capacity t/h 6 8 10 12 15 20 25
Operation Pressure Mpa 1.25/1.6/2.5 1.25/1.6/2.5 1.25/1.6/2.5 1.25/1.6/2.5 1.25/1.6/2.5 1.25/1.6/2.5 1.25/1.6/2.5
Steam Temperature ºC 194//204/226 194//204/226 194//204/226 194//204/226 194//204/226 194//204/226 194//204/226
Water-inlet Temperature ºC 20 20 20 20 105 105 105
 Heating Efficiency % ≥78 ≥78 ≥80 ≥80 ≥81 ≥81 ≥81
Area of Boiler Heating Surface m3 147.8 175 220 388 443 578 626
Area of Stoker m3 7.6 9.6 11.72 14.2 17.2 22.6 26.3
Coal Available II type bitumite,low heat capability:17700-21000KJ/kg
Water Pump Model 2GC-5×6 2½GC-6×6 DG12-25×7 DG15-35×5 DG15-35×5 DG25-35×5 DG46×30
Motor Power KW 15/18.5 15/18.5 18.5/22 22/30 22/30 30/37 37/45
Blast Fan Model G6-41-13
NO7.1A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-73-11
NO11D
G4-68-10D
Ventilation m3/h 5349-10354 9369-18137 9369-18137 9369-18137 9369-18137 36100 33173-
58856
 Wind Pressure Pa 1697-2270 2535-3391 2535-3391 2535-3391 2535-3391 2730 2313-3401
 Motor  Power KW 7.5 18.5 18.5 18.5 18.5 37 45
Induced Draft Fan Model Y6-41-13
NO10C
Y6-41-13
NO11.2D
Y6-41-13
NO11.2D
Y6-41-13
NO11.2D
Y8-39-13
NO10D
GY20-15 Y4-68
NO12.5D
Ventilation m3/h 32144-
16604
41773-
21578
41773-
21578
41773-
21578
4500 73308 60611-
110772
 Wind Pressure Pa 2575-3444 2764-3697 2764-3697 2764-3697 3205 3515 3765-2589
Motor Power KW 37 45 45 55 90 110 132
Dimensions of Biggest Parts for Shipment M 7.83×3.34×
3.46
8.82×3.34×
3.46
8.0×3.5×
2.7
7.2×3.3×
3.6
8.0×3.3×
3.6
10.6×3.35×3.69 10.8×4.46×3.76
Weight of Biggest Parts for Shipment T 48/51/53 56/58/60 96/97/98 102/103/104 107/108/109 152/154/156 210/212/214

Remark: This parameter is just for reference, for exact parameter, subject to our drawings.

Reviews

There are no reviews yet.

Be the first to review “Coal/Biomass/Multi Fuel Fired Steam Boiler”

Your email address will not be published. Required fields are marked *