Biomass/Bagasse /Coco Nut Fired Double Drums Steam Boiler

Biomass/Bagasse /Coco Nut Fired Double Drums Steam Boiler, Find Details and Price about Biomass Fired Rick Husk Fired from Biomass/Bagasse /Coco Nut Fired Double Drums Steam Boiler – QINGDAO HAMMER INDUSTRIES CO., LTD.

Description

SZL Series Steam Boiler Specification
SZL water tube easy installation(assembled) boiler has 2 vertical steam drums, and the
innovative horizontal cyclone-fired combustion chamber, which could effectively enhance
the thermal efficiency and reduce the flue gas emission concentration. The flue gas emission
concentration is lower than 100 mm/nm3, the flue gas blackness is lower than Ringelmann
level 1,which enables the boiler to be used in the first-class environment protected area.
The boiler installs one cast iron economizer at its back body, the fire-gate applies the
chamber-segregated ventilation structure, which is easy to adjust. The separate-layer coal
supply device could be chosen according to the customer requirement. Advantages of
such boiler are: strong power, high thermal efficiency, 110% override capability,
compactly designed, small floor area.

Boiler Model SZL6-1.25/1.6/2.5-AII SZL8-1.25/1.6/2.5-AII SZL10-1.25/1.6/2.5-AII SZL12-1.25/1.6/2.5-AII SZL15-1.25/1.6/2.5-AII SZL20-1.25/1.6/2.5-AII SZL25-1.25/1.6/2.5-AII
Rated Evaporation Capacity t/h 6 8 10 12 15 20 25
Operation Pressure Mpa 1.25/1.6/2.5 1.25/1.6/2.5 1.25/1.6/2.5 1.25/1.6/2.5 1.25/1.6/2.5 1.25/1.6/2.5 1.25/1.6/2.5
Steam Temperature ºC 194//204/226 194//204/226 194//204/226 194//204/226 194//204/226 194//204/226 194//204/226
Water-inlet Temperature ºC 20 20 20 20 105 105 105
 Heating Efficiency % ≥78 ≥78 ≥80 ≥80 ≥81 ≥81 ≥81
Area of Boiler Heating Surface m3 147.8 175 220 388 443 578 626
Area of Stoker m3 7.6 9.6 11.72 14.2 17.2 22.6 26.3
Coal Available II type bitumite,low heat capability:17700-21000KJ/kg
Water Pump Model 2GC-5×6 2½GC-6×6 DG12-25×7 DG15-35×5 DG15-35×5 DG25-35×5 DG46×30
Motor Power KW 15/18.5 15/18.5 18.5/22 22/30 22/30 30/37 37/45
Blast Fan Model G6-41-13
NO7.1A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-73-11
NO11D
G4-68-10D
Ventilation m3/h 5349-10354 9369-18137 9369-18137 9369-18137 9369-18137 36100 33173-
58856
 Wind Pressure Pa 1697-2270 2535-3391 2535-3391 2535-3391 2535-3391 2730 2313-3401
 Motor  Power KW 7.5 18.5 18.5 18.5 18.5 37 45
Induced Draft Fan Model Y6-41-13
NO10C
Y6-41-13
NO11.2D
Y6-41-13
NO11.2D
Y6-41-13
NO11.2D
Y8-39-13
NO10D
GY20-15 Y4-68
NO12.5D
Ventilation m3/h 32144-
16604
41773-
21578
41773-
21578
41773-
21578
4500 73308 60611-
110772
 Wind Pressure Pa 2575-3444 2764-3697 2764-3697 2764-3697 3205 3515 3765-2589
Motor Power KW 37 45 45 55 90 110 132
Dimensions of Biggest Parts for Shipment M 7.83×3.34×
3.46
8.82×3.34×
3.46
8.0×3.5×
2.7
7.2×3.3×
3.6
8.0×3.3×
3.6
10.6×3.35×3.69 10.8×4.46×3.76
Weight of Biggest Parts for Shipment T 48/51/53 56/58/60 96/97/98 102/103/104 107/108/109 152/154/156 210/212/214

Remark: This parameter is just for reference, for exact parameter, subject to our drawings.

Boiler FAQs

Q: What different types of boilers are available?

DZL type steam/hot water boiler
SZL type steam /hot water boiler
SHL type steam /hot water boiler
WNS type steam /hot water boiler
SZS type steam /hot water boiler
SZW type steam /hot water boiler
CFB type steam boiler
YLW type thermal oil boiler/heater
YYL(W) type thermal oil boiler/heater
WNS type thermal oil boiler/heater
SZS type thermal oil boiler/heater
SZW type thermal oil boiler/heater
Waste heat recovery boiler
Steam generator

Q: What is a fire tube steam boiler?

A fire tube steam boiler is a boiler where the combustion gases from the burner are channeled through tubes that are surrounded by the fluid to be heated. The boiler body is the pressure vessel and contains the fluid. In most cases, this fluid is water that will circulate for heating purposes or become steam for use in processing.
Each set of tubes through which the combustion gas passes, before making a turn, is considered a “step”. Consequently, a three-step boiler will have three sets of pipes with the outlet located at the rear of the boiler.

Q: What’s advantages of our boiler?

Wide Range of Fuel Type
Applicable for a various of light oil, furnace oil, natural gas, LNG, biogas, coke gas, methanol, biodiesel, etc.

High Thermal Efficiency
New and unique design with high thermal efficiency, which save running cost of buyer

Unique Control System
Unique three-elements control system with PID unit covered PLC, inverters, and HMI to reach high level automatic running of boiler

Q: What is the turndown ratio of our boilers?

our boilers feature turndown ratios of 5:1, means the boiler’s minimum operating load is 20% of the boiler’s full capacity (100% capacity)

Q: How do I choose the right boiler?

Firstly, check the actual steam pressure and consumption required at present, and discuss with management there are extra steam required or not in next five years.
Secondly, confirm the boiler fuel type, then we will provide you an optimal boiler that take all factors in consideration.

Q: How long does an industrial steam boiler last?

The normal service life of a steam boiler is 10 to 20 years, provided that proper care and maintenance routines are applied to the feedwater and interior of the boiler.
When considering steam boiler replacement, the three most important aspects to consider are safety, economy and changing requirements to perform the function for which it is operating.

Q: What services for industrial boilers does our offer?

we offers its customers the following services for industrial steam boiler, thermal oil boiler and waste heat recovery boilers and steam generators:

Customized boiler designs.
Super quality boiler product
Installation and commissioning service
Operators training service
Lifetime maintenance service.

Q: What safety features do steam boiler have?

Boiler shutdown protection due to water level low
Boiler shutdown protection due to continuous water level low
Boiler shutdown protection due to steam pressure high
Safety valve over pressure protection.
Automatic FWP on / off

Q: What is the lead time of our boiler

The subject boiler will be delivered within 60 -90 days based on boiler capacity

Q: What primary components for boilers are there?

The most common accessories are:
Burner
Economizer and condenser
Feed water pump
Thermal deaerator (if necessary)
Chimney
Control panel
Instrument gauges and valves
we supplies all types of complementary equipment for industrial steam boilers, and designs new equipment and tools if they are necessary for the final installation to meet its clients’ expectations.

Q: What are the optional items of boiler for buyer choose from

Steam and feed water flow meter
Periodic blowdown expander (if necessary)
Continuous blowdown expander (if necessary)
Thermal deaerator (if necessary)

Q: What is the supply scope of boiler arranged by buyer

Whole civil works engineering by our design drawing
All connecting piping (steam, feed water piping)
All connecting cables (motor cables, single cables, main power supply cable)
Some connecting valves from feed water pump point
Chimney manufacture on site by our design drawing
Balance flue gas ducting manufacture on site by our design drawing
Thermal deaerator

Q: How does boiler warranty work?

The subject boiler is covered by a twelve months warranty against mechanical and/ or factory defects from date of test-run or 18 months from the date of shipment whichever comes earlier.
we shall repair or replace the components, parts or accessories covered by warranty that had become inoperative within the warranty period but not covered caused by faulty operation from the buyer.
we will provide lifetime service for boiler with cost when its warranty expired.

Q: Who will be fitting my new boiler?

Simply, a local professional boiler installing company will install the subject boiler under our engineer’s instruction and supervision

Q: How long will my installation & commissioning take?

Typically, the whole installation & commissioning work may take 1-4 months based on the subject boiler capacity.

Q: How often should I maintain my boiler?

Overhaul inspection and maintenance: 1-3 month
we will provide detail brochure regarding how and when to do maintenance work during boiler running.

Reviews

There are no reviews yet.

Be the first to review “Biomass/Bagasse /Coco Nut Fired Double Drums Steam Boiler”

Your email address will not be published. Required fields are marked *